******************************************************************** * IBM Hard Disk Drive Update Program * * Readme.txt Version 1.07 * ******************************************************************** 1.0 Overview 2.0 Change History 3.0 Installation and Setup Instructions 4.0 Configuration Information 5.0 Unattended Mode 6.0 Web Sites and Support Phone Number 7.0 Trademarks and Notices 8.0 Disclaimer 1.0 Overview _____________ 1.1 Overview of this code The IBM Hard Disk Drive Update Program Version 1.07 contains hard disk drive firmware updates. IBM PC Servers, Netfinity Severs and IBM Intellistations with specific SCSI hard disk drive options installed may be affected. The specific drive options are listed below: The Following IBM Hard Disk Drive options may contain drives that will be updated: 94G7491, 94G7492, 02K0477, 02K0478, 02K0439, 94G7098, 94G7099, 94G7429, 94G7430, 01K8053, 01K8055, 02K0440, 02K0441, 01K7956, 01K7959, 01K8501, 02K0442, 01K8009, 01K8054, 01K8503, 39L9806, 39L9807, 36L9808, 01K7960, 01K8499, 01K8500, 36L9809, 36L9810, 36L9811, 36L9744, 36L9745, 36L9746, 36L9748, 36L9749, 36L9750, 37L7199, 37L7200, 37L7201, 37L7202, 37L7203, 37L7204, 37L7205, 37L7206 1.2 Limitations The update program will find the options listed above and only updates the drive firmware as needed. The update supports Hard Disk Drive options installed in IBM PC Servers, Netfinity Servers, or external storage enclosures controlled by any Adaptec 2940/78xx-based SCSI Ultra controllers, Adaptec 2940U2W/79xx-based SCSI Ultra2 controllers, the IBM ServeRAID II family of adapters, the Serveraid III family of adapters and the ServeRaid-4H adapter as well as Hard Disk Drives attached to the IBM Netfinity Fibre Channel RAID Controller. 1.3 Enhancements The updates included in this release will prevent certain drives from not spinning up in certain situations, improves performance and error in other logging in other drives 1.4 Level of Recommendation IBM strongly recommends this update to all customers to prevent premature failure of drives. 1.5 Dependencies Before running the IBM Hard Disk Drive Update, first update IBM ServeRaid family of controllers BIOS/Firmware and the IBM Netfinity Fibre Channel Raid Controller to their latest levels. If the drives you are updating are being used in a Microsoft Cluster Server Environment please carefully read the CLUSTER.TXT file on diskette one. ___________________ 2.0 Change History ___________________ 2.1 IBM Hard Disk Drive Update Program Version 1.00 Initial Release 2.2 IBM Hard Disk Drive Update Program Version 1.00 to 1.01 Added support and code for drive part numbers: 25L1950, 25L1951, 59H6597 2.3 IBM Hard Disk Drive Update Program Version 1.01 to 1.02 Added support and code for drive part number: 08L8421 2.4 IBM Hard Disk Drive Update Program Version 1.02.1 This version for for specific 9.1GB and 18.2GB drives only 2.5 IBM Hard Disk Drive Update Program Version 1.02 to 1.04 Added support and code for drive part numbers: 00K7927, 02K3404, 02K3405, 02K3406, 36L8748, 36L8750, 36L8752, 36L8754, 36L8720, 10L6015, 10L6015, 10L6044, 10L6046, 36L8770, 36L8772, 36L8774, 36L8776, 36L8778, 36L8780, 37L5740, 37L5742 2.6 IBM Hard Disk Drive Update Program Version 1.04 to 1.06 Added support and code for drive part numbers: 25L1950, 25L1951, 25L1952, 25L1953, 25L1958, 25L1959, 09L4058 2.6 IBM Hard Disk Drive Update Program Version 1.06 to 1.07 Added support and code for drive part numbers: 09L4053, 09L4056, 09L4059, 02K3405, 02K3406, 36L8748, 36L8750, 36L8752, 36L8754, 19K1460, 19K1462, 19K1478, 19K1480, 36L8720, 10L6015, 10L6015, 10L6044, 10L6046, 36L8770, 36L8772, 36L8774, 36L8776, 36L8778, 36L8780, 19K1464, 19K1466, 19K1468, 19K1482, 19K1484, 19K1486 ___________________________ 3.0 Installation and Setup ___________________________ 3.1 Updating the Hard Disk Drive Firmware The IBM Hard Disk Drive Update Program will detect if your server has installed drives that require a firmware update. The first screen will indicate which drives if any need to be updated. All others will be marked OK To confirm that the updates have been applied, restart the program and all drives should be marked with a status of OK. 3.1.1 If new logical drives have been created in a RAID5 array with the IBM ServeRaid family of adapters or the Netfinity Fibre Channel Raid Controller, wait until the background initialization/synchronization of the array has completed before attempting to update the drives with the IBM Hard Disk Drive Update Program. 3.1.2 Insert the IBM Hard Disk Drive Update Program - Diskette 1 into the diskette drive; then, turn on the system. If the system is already turned on, press Ctrl+Alt+Del. 3.1.3 Follow the instructions that appear on the screen. 3.1.4 If the status is reported as REPLACE, please contact IBM Service to have the drive replaced. If the status is reported as BAD, please power cycle the systems/drives and reboot the IBM Hard Disk Drive Update Program to see if drive in question has been updated. If it hasn't then please call IBM Service and have it replaced. If it has been updated, continue updating all remaining drives. 3.2 Other After the update completes, you may reboot the system once again with IBM Hard Disk Drive Update Program - Diskette 1 to verify that the hard disk drive firmware has been updated. ______________________________ 4.0 Configuration Information ______________________________ 4.1 There is no configuration required with the IBM Hard Disk Drive Update Program. ____________________ 5.0 Unattended Mode _____________________ 5.1 The IBM Hard Disk Drive Update Program is self booting and requires minimum user input and does not support full unattended mode at this time. _______________________________________ 6.0 WEB Sites and Support Phone Number _______________________________________ 6.1 IBM Support Web Site: http://www.pc.ibm.com/support 6.2 IBM Marketing Netfinity Web Site: http://www.pc.ibm.com/netfinity 6.3 IBM Marketing Intellistaion Web Site: http://www.pc.ibm.com/intellistation 6.4 If you have any questions about this update, or problems applying the update go to the following Help Center World Telephone Numbers URL: http://www.pc.ibm.com/qtechinfo/YAST-3P2QLY.html. __________________________ 7.0 Trademarks and Notices __________________________ 7.1 The following terms are trademarks of the IBM Corporation in the United States or other countries or both: IBM HelpCenter Netfinity Server Intellistation ________________ 8.0 Disclaimer ________________ 8.1 THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND. IBM DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS DOCUMENT. BY FURNISHING THIS DOCUMENT, IBM GRANTS NO LICENSES TO ANY PATENTS OR COPYRIGHTS. 8.2 Note to Government Users Include the following note after the disclaimer paragraph. Note to U.S. Government Users -- Documentation related to restricted rights -- Use, duplication or disclosure is subject to restrictions set forth in GSA ADP Schedule Contract with IBM Corporation.