Enclosure management device object
Use this object, in the Physical devices view, to
work with a storage enclosure attached to controller with a SAF-TE
processor.
Note: The integrated
RAID controller does not support enclosure monitoring. Any enclosure in
an integrated RAID controller RAID subsystem is displayed in the ServeRAID Manager
Enterprise view; however, the ServeRAID Manager and the ServeRAID Manager agent will not
generate any events or enclosure status information.
Possible subobject
None.
Warning and error conditions
(warning) is displayed
if the enclosure has the following conditions:
- A fan has failed.
- A power supply has failed.
(error) is displayed
if the enclosure has the following conditions:
- It is not responding.
- It is overheating.
- Multiple fans have failed.
- Multiple power supplies have failed.
(enclosure) is displayed
if the enclosure is one of the following:
- Working properly.
- Not supported.
- Supported, but not monitored for problems. For example, enclosures that
are internal to a server do not have separate fans or power supplies.
Actions
Identify enclosure
x-0231-SRM-00-06-EN