H01754 - FALSE "DISK CHANGE" TEST FAILURE IN QAPLUS/WIN-WIN SYMPTOM: IBM PC 300 Series 6577 and 6587 preloaded with Windows95 may exhibit a false "Disk Change" test failure when testing the diskette drive subsystem with QAPlus/WIN-WIN. PROBLEM ISOLATION AIDS: Start QAPlus/WIN-WIN in Windows95 and select the floppy subsystem test routine. Disable all other tests except the "Disk Change." Perform the test to recreate the failure. The failure will also occur if the other tests are allowed to execute along with the "Disk Change" test. This failure only affects QAPlus/WIN-WIN in the Windows95 environment. Windows 3.11 does not exhibit the failure. FIX: Do not replace hardware. This is a false error condition. QAPlus/PRO (IBM PC 300/700 Diagnostic diskette) should be used to verify proper operation of the diskette drive subsystem. QAPlus/WIN-WIN, included in the systems preloaded software, is being updated to eliminate this failure. An updated version of the application should be available from the IBM PC Company BBS on 6/1/96 in the PC 300/700 Files section (#21). QAPLUS/WIN-WIN is a trademark of Diagsoft, Inc. Windows & Windows95 are trademarks of the Microsoft Corporation.