H132209 - 166 POST ERROR WITH IBM SERVERGUARD ADAPTER SYMPTOM: During POST (Power-On System Test) a 166 error is received indicating the installed ServerGuard Adapter is "busy." PROBLEM ISOLATION AIDS: ALL PS/2 Servers with the serverguard adapter, FRU P/N06H8091, installed may be affected. FIX: Do not replace the ServerGuard Adapter. This error may be caused by either inserting or removing the modem from the PCMCIA socket, or connecting/disconnecting the battery-pack to the adapter while system power is on. TO CORRECT THE PROBLEM: 1. Power off the system, then remove the adapter. 2. Make sure the battery-pack is fully charged. 3. Disconnect the battery-pack from the adapter for a few seconds. 4. Reconnect the battery-pack, and make sure the 3 LED's, located on top of the PCMCIA modem socket, follow this sequence: - CR3 comes on first. - Seconds later, CR2 blinks 5 TIMES in a 5 second time interval, then stays on for a few seconds and goes off. - Seconds later, CR3 goes off. - CR1 remains off the whole time. If problems continue, use normal problem isolation procedures. Jan 16, 1996