H132256 - SERVER 320 & 520 ERRONEOUS CONFIGURATION ERROR MESSAGE SYMPTOM: When the PC Servers 320 & 520 (EISA models) are booted from the EISA Configuration Diskette (version 3.30), the following message is seen: Configuration Changes The following changes have automatically been made: Boards removed: Embedded 10690001 PROBLEM ISOLATION AIDS: The system is an IBM PC Server 320 or 520 (EISA models only) with the SCSI-2 PCI RAID Adapter option (FRU P/N06H5078) installed . FIX: The error message should be disregarded. No hardware has failed and none should be replaced. Engineering investigation has identified the problem and a new revision of the System BIOS and the EISA Configuration Diskettes is in process to resolve the problem. This tip will be updated with the appropriate information when the revisions are available. Update Mar 11, 1996