H137343: 2625 ECA002 - 365X & XD BASE SHIELD UPGRADE KIT. PURPOSE: Install the Base Shield ECA Kit on systems that match the PHYSICAL CHECK criteria. FEATURES: Type, Machines Affected Model, With and/or Feature/Device B/M to be Service System Stage B/M Description Installed Hours Hours 2625 B/M9999999 MOD 365X XD B/M73H8598 00.3 00.1 PHYSICAL CHECK: Inspect for an ECA label or black mark beneath the battery at the front inner edge of the system base. If this area is blank, install the Base Shield ECA Kit during the installation of any FRU listed in figure 1. __________________________________________________ |FIG 1 | | | | Parts Description FRU P/N | | ---------------------------- -------------- | | System board card assembly P/N69H7908 | | CPU card assembly P/N69H7912 (P100) | | P/N74H0237 (P120) | | P/N82H8162 (P133) | | Base cover assembly P/N69H7903 | | Base Insulator (*) P/N69H7916 | |__________________________________________________| * Contained in the Miscellaneous Base Parts kit P/N69H7916. PREREQUISITES: NONE COMPANION: NONE CONCURRENT: NONE DETAIL: The inner bottom of the system is covered with an aluminum mylar sheet, except for two 31mm square areas. The Shield Kit should be installed in these areas during a repair action on any FRU listed in Fig 1 of the PHYSICAL CHECK. The kit is FRU P/N73H8598. It contains self stick aluminum mylar patches and detailed instructions. The patches should be placed in the blank spots located on the inside the base at the external leg indents. The ECA002 Label should be placed beneath and in front of the battery at the front edge of the system base. Both of these locations are shown in the following diagram and in detail in the instruction sheet. ________________________ | | | -- Patch -- |<--Base | -- <--- areas---> -- | | ______| | | | Diskette or CD| | <-----Battery Compartment compartment------> | | | | | |_____________________---|<--ECA002 Label Location NOTES: This ECA will expire on April 30, 2000. Order FRU kit P/N73H8598. worked 990.