H137977 - PC SERVER 704 ABEND: DIVIDE BY ZERO EXCEPTION SYMPTOM: The following message is displayed on the PC Server 704: "ABEND: Divide by Zero exception" PROBLEM ISOLATION AIDS: - The Server has two(2) or more processors - The Server is under heavy load running NetWare SMP 4.11 Note: This condition is aggravated while running Vinca StandBy Server. FIX: Use the following procedure: 1. Download, expand, and install the NetWare patches from the file IWSP2.EXE located on the following Novell WEB URL: http://support.novell.com/search/patlst.htm 2. Change the following statement in the C: NWSERVER STARTUP.NCF from: "LOAD MPS14" to: "LOAD MPS14 -FB" The -FB parameter changes the virutal wire mode. Novell and NetWare are trademarks of Novell, Inc. Vinca is a trademark of Vinca Corporation. June 5, 1997