Record number: H16198 Device: D/T6282 Model: M Hit count: UHC00000 Success count: USC0000 Publication code: PC50 Tip key: Date created: O97/06/24 Date last altered: A97/06/24 Owning B.U.: USA Abstract: INTERMITTENT POWER-ON FAILURE ON IBM PC300-GL SYMPTOM: IBM PC300-GL 6272/6282 systems intermittently fail to power on. PROBLEM ISOLATION AIDS: In some systems the HD drive and power LED cables may be secured too tightly with the LED wire tie wraps. This can cause the insulation on the LED wires to become damaged resulting in an intermittent short. If the system exhibits the symptom described above, examine the LED cables for damage that may expose the inner wire resulting in a possible short. FIX: If the insulation on one or both of the LED wires is damaged, replace them with the following FRU numbers: HDD LED and Cable FRU 93F2388 Power LED and Cable FRU 93F2389 SAS KEYWORDS: PSY2 PSY2MISC PSY2PART PSVP PSVPMISC PSVPMISC D/T6272 D/T6282 D/T6560 6272 6282 6560 UNCLASSIFIED