Record number: H163815 Device: D/T6898 Model: M Hit count: UHC00029 Success count: USC0000 Publication code: PC50 Tip key: Date created: O98/06/01 Date last altered: A98/06/15 Owning B.U.: USA Abstract: SCSI BIOS ERROR: "SCSI TERMINATION NOT FOUND" SYMPTOM: When booting the system, the SCSI BIOS returns the following, or similar error message: "SCSI Termination Not Found" The SCSI subsystem will not be enabled. PROBLEM ISOLATION AIDS: This tip applies to IBM IntelliStation M-Pro Series 6898 and Netfinity 3500 Series 8644 systems. The "SCSI Termination Not Found" error message will manifest itself as an "out-of-box" error in new systems preconfigured for SCSI operation. In systems preconfigured for IDE operation, the SCSI error message may not be seen until the on-board SCSI BIOS is enabled in the F1 Setup utility, and a SCSI hardfile is in- stalled. Planar FRU numbers exposed to this condition are P/N93H7269 and P/N08L0046 (for 333MHz Models). FIX: Follow normal problem determination steps to eliminate possible SCSI adapter, SCSI cable, or SCSI hardfile errors. If the "SCSI Termination Not Found" error persists, replace the system board with FRU P/N08L0606. Note: When servicing Netfinity 3500, Type 8644-1xx/2xx systems, see Retain Tip H106654 for instructions on planar replacement, and saving the CMOS configuration. SAS KEYWORDS: PSY2 PSY2ERR PWS PWSERR D/T6898 6898 NETFINITY 3500 8644 UNCLASSIFIED 93H7269 08L0606 RF1 FUSE